Loading... Please wait...The Enphase Energy Microinverter System improves energy harvest, increases reliability, and dramatically simplifies design, installation and management of solar power systems. The Enphase System includes the microinverter, the Envoy Communications Gateway, and Enlighten, Enphase’s monitoring and analysis software.
|
|
M215 |
|
|
Input Data (DC) |
M215-60-2LL-S22/S23 |
|
|
Recommended Maximum Input Power (STC): |
260W |
|
|
Maximum Input DC Voltage: |
45V |
|
|
Peak Power Tracking Voltage: |
22V – 36V |
|
|
Operating Range: |
16V – 36V |
|
|
Min./Max. Start Voltage: |
26.4V/45V |
|
|
Max. DC Short Circuit Current: |
15A |
|
|
Max. Input Current: |
10.5A |
|
|
Output Data (AC) |
@208 Vac |
@240 Vac |
|
Maximum Output Power: |
215W |
|
|
Nominal Output Current: |
1.0 A* |
0.9 A* |
|
Nominal Voltage/Range: |
208V/183V-229V |
240V/211V-264V |
|
Extended Voltage/Range: |
208V/179V-232V |
240V/206V-269V |
|
Nominal Frequency/Range: |
60.0/59.3-60.5 |
|
|
Extended Frequency/Range: |
60.0/59.2-60.6 |
|
|
Power Factor: |
>0.95 |
|
|
Maximum Units Per Branch: |
25 (three phase) |
17 (single phase) |
|
Maximum Output Fault Current: |
1.05 Arms, over 3 cycles; 25.2 Apeak, 1.74ms duration |
|
|
Efficiency |
||
|
CEC Weighted Efficiency: |
96.0% |
|
|
Peak Inverter Efficiency: |
96.3% |
|
|
Static MPPT Efficiency (weighted, reference EN 50530): |
99.8% |
|
|
Dynamic MPPT Efficiency (fast irradiation changes, reference EN 50530): |
99.9% |
|
|
Night Time Power Consumption: |
46mW |
|
|
Mechanical Data |
||
|
Ambient Temperature Range: |
-40°C to +65°C |
|
|
Operating Temperature Range (internal): |
-40°C to +85°C |
|
|
Dimensions (W x H x D): |
17.3 cm x 16.4 cm x 2.5 cm (6.8” x 6.45” x 1.0”)** |
|
|
Weight: |
1.6 kg (3.5 lbs) |
|
|
Cooling: |
Natural Convection - No Fans |
|
|
Enclosure Environmental Rating: |
Outdoor - NEMA 6 |
|
|
Features |
||
|
Compatibility: |
Pairs with most 60-cell PV modules |
|
|
Communication: |
Powerline |
|
|
Warranty: |
25-year limited warranty |
|
|
Compliance: |
UL1741/IEEE1547, FCC Part 15 Class B |
|
*Arms at nominal voltage.
**Without mounting bracket.
Specifications subject to change without notice.
Posted by jolson on 2nd Jan 2010
Ground array in N. Carolina
I installed 14 enphase units on racking and placed 14 CSI 230 watt panels on the rack mount - ran a branch 220 volt line into the main circuit panel on a 15 amp breaker, and everything works well - Envoy monitoring unit worked right out of the box - plugged into home network via ethernet cable and as soon as sunlight hit the panels, the monitor unit started polling the Enphase modules and sending the info over the web. Took three days for the factory to complete the web interface for monitoring each panel with daily, weekly, yearly, and total information on produced power. Way more information than I expected, ad the internet access is just fantastic. I can even get an up-to-the-minute wattage output report on my mobile phone. I am one happy customer.